Welcome to the GoFuckYourself.com - Adult Webmaster Forum forums.

You are currently viewing our boards as a guest which gives you limited access to view most discussions and access our other features. By joining our free community you will have access to post topics, communicate privately with other members (PM), respond to polls, upload content and access many other special features. Registration is fast, simple and absolutely free so please, join our community today!

If you have any problems with the registration process or your account login, please contact us.

Post New Thread Reply

Register GFY Rules Calendar
Go Back   GoFuckYourself.com - Adult Webmaster Forum > >
Discuss what's fucking going on, and which programs are best and worst. One-time "program" announcements from "established" webmasters are allowed.

 
Thread Tools
Old 10-25-2005, 10:51 PM   #1
Juicy D. Links
So Fucking Banned
 
Industry Role:
Join Date: Apr 2001
Location: N.Y. -Long Island --
Posts: 122,992
Izzy

Originally Posted by MrIzzz
you need to have quad shield rg59 throughout your house with no splitters except for the main one coming into the house. make sure all connectors are crimped not twist ons



Fucker seriosly come over one day and help me rewire one line.
Juicy D. Links is offline   Share thread on Digg Share thread on Twitter Share thread on Reddit Share thread on Facebook Reply With Quote
Old 10-25-2005, 10:52 PM   #2
MrIzzz
If u touch it, I will cum
 
Join Date: Sep 2003
Location: long island
Posts: 22,923
lol, i replied in your other thread!!!!!!!!
__________________


WHO WANTS TO PLAY GRAB-ASS?
MrIzzz is offline   Share thread on Digg Share thread on Twitter Share thread on Reddit Share thread on Facebook Reply With Quote
Old 10-25-2005, 10:55 PM   #3
Juicy D. Links
So Fucking Banned
 
Industry Role:
Join Date: Apr 2001
Location: N.Y. -Long Island --
Posts: 122,992
Quote:
Originally Posted by MrIzzz
lol, i replied in your other thread!!!!!!!!
ok we doing lunch tomorrw?
Juicy D. Links is offline   Share thread on Digg Share thread on Twitter Share thread on Reddit Share thread on Facebook Reply With Quote
Old 10-25-2005, 11:01 PM   #4
MrIzzz
If u touch it, I will cum
 
Join Date: Sep 2003
Location: long island
Posts: 22,923
Quote:
Originally Posted by Juicy D. Links
ok we doing lunch tomorrw?
i'll call you tomorrow sweetie
__________________


WHO WANTS TO PLAY GRAB-ASS?
MrIzzz is offline   Share thread on Digg Share thread on Twitter Share thread on Reddit Share thread on Facebook Reply With Quote
Old 10-25-2005, 11:02 PM   #5
Marcus Aurelius
No Refunds Issued.
 
Marcus Aurelius's Avatar
 
Industry Role:
Join Date: Apr 2003
Posts: 14,809
If your rewiring for cable RG-59 is a mistake You can get away with it but its better to upgrade. Go with RG-6, its the standard for most cable companies now due to the higher signal demands for digital systems and the DB loss per foot is less than RG-59. Crimp not twist connectors is the way to go and if you can get them, snap and seal connectors are the preferred way to cap your lines, and a single splitter at the wall junction is best, in house splitters will only cause you grief. Go with that setup and you'll be ready for satellite, cable, whatever you wanna throw at it.

And if you are a fiend go with RG-11 through the whole house, although there is no need for it and its overkill you'll have almost no DB loss whatsoever for the short runs required for in house wiring.

(I worked for charter a few years)
Marcus Aurelius is offline   Share thread on Digg Share thread on Twitter Share thread on Reddit Share thread on Facebook Reply With Quote
Old 10-25-2005, 11:02 PM   #6
Deej
I make pixels work
 
Deej's Avatar
 
Industry Role:
Join Date: Jun 2005
Location: I live here...
Posts: 24,386
how cute...love birds
__________________

Deej's Designs n' What Not
Hit me up for Design, CSS & Photo Retouching


Icq#30096880
Deej is offline   Share thread on Digg Share thread on Twitter Share thread on Reddit Share thread on Facebook Reply With Quote
Old 10-25-2005, 11:05 PM   #7
Deej
I make pixels work
 
Deej's Avatar
 
Industry Role:
Join Date: Jun 2005
Location: I live here...
Posts: 24,386
You guys should get facials too
__________________

Deej's Designs n' What Not
Hit me up for Design, CSS & Photo Retouching


Icq#30096880
Deej is offline   Share thread on Digg Share thread on Twitter Share thread on Reddit Share thread on Facebook Reply With Quote
Old 10-25-2005, 11:07 PM   #8
MrIzzz
If u touch it, I will cum
 
Join Date: Sep 2003
Location: long island
Posts: 22,923
Quote:
Originally Posted by mdcq
If your rewiring for cable RG-59 is a mistake You can get away with it but its better to upgrade. Go with RG-6, its the standard for most cable companies now due to the higher signal demands for digital systems and the DB loss per foot is less than RG-59. Crimp not twist connectors is the way to go and if you can get them, snap and seal connectors are the preferred way to cap your lines, and a single splitter at the wall junction is best, in house splitters will only cause you grief. Go with that setup and you'll be ready for satellite, cable, whatever you wanna throw at it.

And if you are a fiend go with RG-11 through the whole house, although there is no need for it and its overkill you'll have almost no DB loss whatsoever for the short runs required for in house wiring.

(I worked for charter a few years)
would i notice any difference with rg11 throughout my house? i did mine with rg6 a few months back, no splitters, etc... and i love it
__________________


WHO WANTS TO PLAY GRAB-ASS?
MrIzzz is offline   Share thread on Digg Share thread on Twitter Share thread on Reddit Share thread on Facebook Reply With Quote
Old 10-25-2005, 11:08 PM   #9
MrIzzz
If u touch it, I will cum
 
Join Date: Sep 2003
Location: long island
Posts: 22,923
Quote:
Originally Posted by Deej
You guys should get facials too
jealousy jealousy!!!! although we could use some eyebrow waxing
__________________


WHO WANTS TO PLAY GRAB-ASS?
MrIzzz is offline   Share thread on Digg Share thread on Twitter Share thread on Reddit Share thread on Facebook Reply With Quote
Old 10-26-2005, 07:47 AM   #10
Juicy D. Links
So Fucking Banned
 
Industry Role:
Join Date: Apr 2001
Location: N.Y. -Long Island --
Posts: 122,992
Quote:
Originally Posted by mdcq
If your rewiring for cable RG-59 is a mistake You can get away with it but its better to upgrade. Go with RG-6, its the standard for most cable companies now due to the higher signal demands for digital systems and the DB loss per foot is less than RG-59. Crimp not twist connectors is the way to go and if you can get them, snap and seal connectors are the preferred way to cap your lines, and a single splitter at the wall junction is best, in house splitters will only cause you grief. Go with that setup and you'll be ready for satellite, cable, whatever you wanna throw at it.

And if you are a fiend go with RG-11 through the whole house, although there is no need for it and its overkill you'll have almost no DB loss whatsoever for the short runs required for in house wiring.

(I worked for charter a few years)
Cool thanks yo , Izzy get some of this shit for me.
Juicy D. Links is offline   Share thread on Digg Share thread on Twitter Share thread on Reddit Share thread on Facebook Reply With Quote
Old 10-26-2005, 07:49 AM   #11
Basic_man
Programming King Pin
 
Basic_man's Avatar
 
Industry Role:
Join Date: Oct 2003
Location: Montreal
Posts: 27,360
Quote:
Originally Posted by mdcq
If your rewiring for cable RG-59 is a mistake You can get away with it but its better to upgrade. Go with RG-6, its the standard for most cable companies now due to the higher signal demands for digital systems and the DB loss per foot is less than RG-59. Crimp not twist connectors is the way to go and if you can get them, snap and seal connectors are the preferred way to cap your lines, and a single splitter at the wall junction is best, in house splitters will only cause you grief. Go with that setup and you'll be ready for satellite, cable, whatever you wanna throw at it.

And if you are a fiend go with RG-11 through the whole house, although there is no need for it and its overkill you'll have almost no DB loss whatsoever for the short runs required for in house wiring.

(I worked for charter a few years)
Thanks for all the tips mate
__________________
UUGallery Builder - automated photo/video gallery plugin for Wordpress!
Stop looking! Checkout Naked Hosting, online since 1999 !
Basic_man is offline   Share thread on Digg Share thread on Twitter Share thread on Reddit Share thread on Facebook Reply With Quote
Post New Thread Reply
Go Back   GoFuckYourself.com - Adult Webmaster Forum > >

Bookmarks



Advertising inquiries - marketing at gfy dot com

Contact Admin - Advertise - GFY Rules - Top

©2000-, AI Media Network Inc



Powered by vBulletin
Copyright © 2000- Jelsoft Enterprises Limited.