You are currently viewing our boards as a guest which gives you limited access to view most discussions and access our other features. By joining our free community you will have access to post topics, communicate privately with other members (PM), respond to polls, upload content and access many other special features. Registration is fast, simple and absolutely free so please, join our community today!

If you have any problems with the registration process or your account login, please contact us.

Post New Thread Reply

Register GFY Rules Calendar Mark Forums Read
Go Back   GoFuckYourself.com - Adult Webmaster Forum > >
Discuss what's fucking going on, and which programs are best and worst. One-time "program" announcements from "established" webmasters are allowed.

 
Thread Tools
Old 09-25-2004, 07:24 PM   #1
PinkMonkey
Confirmed User
 
Join Date: Dec 2002
Location: Vancouver
Posts: 189
Router question

When running a router when do you notice a speed drop on the computer....for example...My computer is about 80 feet from my router. I'm not using wireless, i custom installed a Cat5 cable...but my computer is running a hell of alot slower then the one in the family room.....Any suggestions??
__________________
www.emilysweet.com
www.coinscuties.com

Flee the Country and Grow Some Dreds!!!
PinkMonkey is offline   Share thread on Digg Share thread on Twitter Share thread on Reddit Share thread on Facebook Reply With Quote
Old 09-25-2004, 07:28 PM   #2
baddog
So Fucking Banned
 
Industry Role:
Join Date: Apr 2001
Location: the beach, SoCal
Posts: 107,089
are you using a store bought CAT5 connection, or did you attach the male connector yourself?
baddog is offline   Share thread on Digg Share thread on Twitter Share thread on Reddit Share thread on Facebook Reply With Quote
Old 09-25-2004, 07:30 PM   #3
PinkMonkey
Confirmed User
 
Join Date: Dec 2002
Location: Vancouver
Posts: 189
I have a friend that does the connections...he is a professional.
__________________
www.emilysweet.com
www.coinscuties.com

Flee the Country and Grow Some Dreds!!!
PinkMonkey is offline   Share thread on Digg Share thread on Twitter Share thread on Reddit Share thread on Facebook Reply With Quote
Old 09-25-2004, 07:30 PM   #4
Vitasoy
GFY HALL OF FAME DAMMIT!!!
 
Join Date: Oct 2003
Posts: 58,202
Try another cable? See if you get the same results.
__________________


[email protected]
Vitasoy is offline   Share thread on Digg Share thread on Twitter Share thread on Reddit Share thread on Facebook Reply With Quote
Old 09-25-2004, 07:34 PM   #5
baddog
So Fucking Banned
 
Industry Role:
Join Date: Apr 2001
Location: the beach, SoCal
Posts: 107,089
Quote:
Originally posted by PinkMonkey
I have a friend that does the connections...he is a professional.
I am a professional too, that is why I stopped making cables, they make much better ones at the factory. I am willing to bet you have a hi-resist open on one end of one conductor

Like Vitasoy said, try another cable (store bought this time) and see if it helps.
baddog is offline   Share thread on Digg Share thread on Twitter Share thread on Reddit Share thread on Facebook Reply With Quote
Old 09-25-2004, 07:37 PM   #6
irishfury
Confirmed User
 
Join Date: Aug 2003
Location: In the hearts of cowards
Posts: 2,611
Yeah try another cable...You should be find too about 100 meters
__________________
Trust no one there all snakes
irishfury is offline   Share thread on Digg Share thread on Twitter Share thread on Reddit Share thread on Facebook Reply With Quote
Old 09-25-2004, 07:39 PM   #7
Tom_PMs
Confirmed User
 
Join Date: Jun 2004
Posts: 2,049
The hell with what everyone else says.
I say try a new cable.
__________________

You've read it, you can't unread it.
Tom_PMs is offline   Share thread on Digg Share thread on Twitter Share thread on Reddit Share thread on Facebook Reply With Quote
Old 09-25-2004, 07:43 PM   #8
baddog
So Fucking Banned
 
Industry Role:
Join Date: Apr 2001
Location: the beach, SoCal
Posts: 107,089
This is what I do, and I do them all the time.

Run CAT5 cable between router and workstation.

Terminate both ends of the cable with a CAT5 RJ45 female connector.

Buy 2 CAT5 (or 6 if you wish) patch cables and connect RJ45's to the router and NIC card as applicable
baddog is offline   Share thread on Digg Share thread on Twitter Share thread on Reddit Share thread on Facebook Reply With Quote
Old 09-25-2004, 09:29 PM   #9
pornguy
Too lazy to set a custom title
 
pornguy's Avatar
 
Industry Role:
Join Date: Mar 2003
Location: Homeless
Posts: 62,911
Ok Pro's is there any value to using the new cat6???
__________________
PornGuy skype me pornguy_epic

AmateurDough The Hottes Shemales online!
TChicks.com | Angeles Cid | Mariana Cordoba | MAILERS WELCOME!
pornguy is offline   Share thread on Digg Share thread on Twitter Share thread on Reddit Share thread on Facebook Reply With Quote
Old 09-25-2004, 09:41 PM   #10
baddog
So Fucking Banned
 
Industry Role:
Join Date: Apr 2001
Location: the beach, SoCal
Posts: 107,089
Quote:
Originally posted by pornguy
Ok Pro's is there any value to using the new cat6???
well, as they say, a chain is only as strong as its weakest link, and since there are no CAT 6 connectors (that I am aware of anyway) I don't really see the point.

to be honest, I buy all of my materials at a wholesale supplies warehouse and they don't even offer CAT6 . . . . I only see that at CompUSA, or Frye's, or other retail stores, so I think it is just a marketing ploy.

I have not figured out what the difference is. A tighter twist? Better grade of copper? Prettier colors available for the insulation?
baddog is offline   Share thread on Digg Share thread on Twitter Share thread on Reddit Share thread on Facebook Reply With Quote
Old 09-25-2004, 09:59 PM   #11
Lycanthrope
Confirmed User
 
Lycanthrope's Avatar
 
Industry Role:
Join Date: Jan 2004
Location: Wisconsin
Posts: 4,517
My "real" job is designing cabling systems, preparing RFPs, budgets, etc.... and I have 7 years of installation experience behind it. That said, I feel qualified to answer your question.

Baddog, there are Cat 6 connectors, but neither Cat 6 cabling nor connectors (jacks) are required for this. Cat 5 was developed for future applications, and I usually only recommend it for higher tech, higher spending companies when doing complete systems.

Though this short length should be fine with "homemade" patch cables, as has already been said, you shouldn't do it. Factory made cables are recommended. One nicked or kinked wire in a cable assembly can have very negative results on packet loss which converts to lower speed. Factory made cables are tested for not only continuity and correct wiremapping, but for other things relevant to data transmission such as signal to noise ratio, cross talk... etc.

The current "standard" is Category 5e, which basically allows increased performance in complete channels (end to end connectivity) over straight "Cat 5".

Anyfuck, if it is working at all, at this low distance, I'm guessing it is something else, maybe a flakey port on the router switch. A connection will not be (noticably) slower because of length at these distances because the standars were written for a maximum channel length of 100 meters, which you are in no danger of ever nearing.

Try a new, manufactured cable, if that doesn't work switch ports.
__________________
Lycanthrope is offline   Share thread on Digg Share thread on Twitter Share thread on Reddit Share thread on Facebook Reply With Quote
Old 09-25-2004, 10:04 PM   #12
Lycanthrope
Confirmed User
 
Lycanthrope's Avatar
 
Industry Role:
Join Date: Jan 2004
Location: Wisconsin
Posts: 4,517
Quote:
Originally posted by baddog
well, as they say, a chain is only as strong as its weakest link, and since there are no CAT 6 connectors (that I am aware of anyway) I don't really see the point.

to be honest, I buy all of my materials at a wholesale supplies warehouse and they don't even offer CAT6 . . . . I only see that at CompUSA, or Frye's, or other retail stores, so I think it is just a marketing ploy.

I have not figured out what the difference is. A tighter twist? Better grade of copper? Prettier colors available for the insulation?
Basically Baddog, Category 5 and Category 5e are tested to 100 Mhz (Category 5e providing more headroom) while Category 6 is tested to a minimum of 250 Mhz. While it started out, and still is largely a marketing ploy, there is a difference and new buildings, in my opinion, should be cabled to Category 6 specs
__________________
Lycanthrope is offline   Share thread on Digg Share thread on Twitter Share thread on Reddit Share thread on Facebook Reply With Quote
Post New Thread Reply
Go Back   GoFuckYourself.com - Adult Webmaster Forum > >

Bookmarks
Thread Tools



Advertising inquiries - marketing at gfy dot com

Contact Admin - Advertise - GFY Rules - Top

©2000-, AI Media Network Inc



Powered by vBulletin
Copyright © 2000- Jelsoft Enterprises Limited.